SAFETY CABINET

BIO SAFETY CABINET

Specifications
  • Cabinet enclosure designed Class II Type A2 provides personnel, product and environmental protection from hazardous particles such as bacteria, viruses and genetically manipulated materials such as nucleic acids that require Biosafety Level 1, 2 or 3 containments.
Art No. JSCB-900SB JSCB-1200SB JSCB-1500SB JSCB-1800SB
Working Width 830 mm (3 ft) 1205 mm(4 ft) 1490 mm (5 ft) 1790 mm (6 ft)
Dimensions Inner 830x526x585 1205x526x585 1490x526x585 1790x526x585
W x D x H mm Outer 900x792x1990 1275x792x1990 1560x792x1990 1860x792x1990
HEAP Filter 0.3 um particle removal 99.993 % ~ 99.995 %
ULPA Filter Option 0.12 um particle removal 99.999 %
Air Circulation 70 % Recirculation / 30 % Exhaust
Controller Display Back Light Digital LCD
Speed Control 9 Step Air Velocity Control from 0.3 m/sec. ~ 0.6 m/sec.
Control FL Lamp, UV Lamp, Blower ON/OFF, UV Timer,
Total Using Timer, Filter Replace
Working Lamp FL 20 W x 2 ea FL 30 W x 2 ea FL 30 W x 2 ea FL 36 W x 2 ea
Germicidal UV Lamp UV 20 W x 1 ea UV 30 W x 1 ea UV 30 W x 1 ea UV 40 W x 1 ea
  • Integrated Digital microprocessor control system with back-light LCD display
  • Fan ON/OFF and 9-step adjustable air velocity
  • Fluorescent lamp ON/OFF
  • UV lamp ON/OFF
  • Adjustable UV sterilization timer
  • Elapsed time counter and alarm for HEPA filter replacement
Performance
  • Biological Safety Level Class II Type A2 design provides a higher level of personnel, product and cross contamination protection by keep filtrate airborne particles from the air stream
  • Inflow moves from the room air is drawn into the inlet grille at the work access opening and pass through a negative pressure planum to blower creates HEPA filtered down ward laminar air stream over the work area
  • Approximately 70% of the HEPA-filtered air is re-circulated through the cabinet into the work zone, while 30% passes through an exhaust HEPA filter and is discharged into the laboratory room air
  • Aluminum Frame Mini-pleated HEPA filters with nominal filtration efficiency of 99.993% ~ 99.995% for
    airborne particles larger than 0.3 um
Convenience
  • Ergonomic arm rest
  • Removable working zone plate for easy cleaning and decontamination
  • Front service access panel for comfortable maintenance
  • The front door can also be closed fully to keep the cabinet interior clean during non-use period as well as to prevent exposure to UV radiation during sterilization
  • Epoxy powder coated SPCC exterior for durability
  • Silent and vibration free blower fan motor for comfortable working environment
  • 253 nm Germicidal UV lamp on working zone
  • Supplied with Base Stand with caster
Safety
  • UV Lamp CUT-OFF
    In case of fluorescent lamp turned on
  • TOTAL USING TIME LOG
  • HEAP Filter replacement alarm
  • OVER CURRENT CUT-OFF : Fuse

LAMINAR FLOW CABINET

Specifications
  • Vertical Laminar Flow Cabinet enclosure designed to maintain ISO Class 5 (formerly Class 100) clean air.HEPA filtered laminar air down flow over the work area to protect products or samples being handled in the cabinet from dust or biological contaminants such as bacteria, fungus and genetic materials.
  • Various applications in plant tissue culture, microbial inoculation, media preparation,PCR, electronic or medical parts inspection and assembly where dust particles and contaminants should not be present in the air of working area essentially needed.
Art No. JSCB-900SL JSCB-1200SL JSCB-1500SL JSCB-1800SL
Working Width 830 mm (3 ft) 1205 mm(4 ft) 1490 mm (5 ft) 1790 mm (6 ft)
Dimensions Inner 830x526x585 1205x526x585 1490x526x585 1790x526x585
W x D x H mm Outer 900x792x1990 1275x792x1990 1560x792x1990 1860x792x1990
HEAP Filter 0.3 um particle removal 99.993 % ~ 99.995 %
ULPA Filter Option 0.12 um particle removal 99.999 %
Air Circulation Vertical Laminar Flow
Controller Display Back Light Digital LCD
Speed Control 9 Step Air Velocity Control from 0.3 m/sec. ~ 0.6 m/sec.
Control FL Lamp, UV Lamp, Blower ON/OFF, UV Timer,
Total Using Timer, Filter Replace
Working Lamp FL 20 W x 2 ea FL 30 W x 2 ea FL 30 W x 2 ea FL 36 W x 2 ea
Germicidal UV Lamp UV 20 W x 1 ea UV 30 W x 1 ea UV 30 W x 1 ea UV 40 W x 1 ea
Utility 2 x Power Consent, 1 x Gas Cock, 1 x Air Cock
Electric Requirement 220VAC 50/60Hz 1P
Power Rating 1.0 Amp 1.5 Amp 1.5 Amp 1.6 Amp
  • Integrated Digital microprocessor control system with back-light LCD display
  • Fan ON/OFF and 9-step adjustable air velocity
  • Fluorescent lamp ON/OFF
  • UV lamp ON/OFF
  • Adjustable UV sterilization timer
  • Elapsed time counter and alarm for HEPA filter replacement
Performance
  • The contaminated room air intake through pre-filter and blower create HEPA filtered down ward laminar air stream over the work area which flows towards sash door to protect products or samples in the cabinet being handled from dust or biological contaminants such as bacteria or fungus.
  • Aluminum Frame Mini-pleated HEPA filters with nominal filtration efficiency of 99.993% ~ 99.995% for
    airborne particles larger than 0.3 um
  • Optional ULPA filter had higher filtration efficiency of 99.999% for airborne particles larger than 0.12 um
  • The front door can also be closed fully to keep the cabinet interior clean during non-use period as well as to prevent
    exposure to UV radiation during sterilization
Convenience
  • Ergonomic arm rest
  • Removable working zone plate for easy cleaning and decontamination
  • Front service access panel for comfortable maintenance
  • The front door can also be closed fully to keep the cabinet interior clean during non-use period as well as to prevent exposure to UV radiation during sterilization
  • Epoxy powder coated SPCC exterior for durability
  • Silent and vibration free blower fan motor for comfortable working environment
  • Cold white fluorescent lamp working light
  • 253 nm Germicidal UV lamp on working zone and Supplied with Base Stand with caster
Safety
  • UV Lamp CUT-OFF
    In case of fluorescent lamp turned on
  • TOTAL USING TIME LOG
  • HEAP Filter replacement alarm
  • OVER CURRENT CUT-OFF : Fuse