AUTOCLAVE/BLOCK HEATER

AUTOCLAVE

Specifications
  • JSAT-Series Autoclave, Steam Sterilizer is an innovative replacement of conventional laboratory autoclave by providing reliable performance, up-to-dated design and safety door inter-lock system integrated with temperature and pressure for perfect user safety.
Art No. JSAT-45 JSAT-65 JSAT-85 JSAT-105
Chamber Volume 45 L 65 L 85 L 105 L
Dimensions Inner Ø350 x H475 Ø350 x H680 Ø450 x H535 Ø450 x H665
W x D x H mm Usable Ø350 x H420 Ø350 x H625 Ø450 x H480 Ø450 x H610
Outer 505 x 650 x 975 505 x 650 x 1180 605 x 750 x 1035 605 x 750 x 1165
Basket Ø330 x H195 Ø330 x H295 Ø430 x H225 Ø430 x H290
Temperature Range Up to 123 oC
Accuracy at 121 oC ± 0.5 oC
Uniformity at 121 oC ± 2.0 oC
No. of Service Basket 2
Heater Capacity 2.0 kW 3.0 kW 4.0 kW 5.0 kW
Power Rating 9.2 Amp 13.7 Amp 18.2 Amp 22.8 Amp
Electrical Requirements 220 VAC 50/60Hz 1 Phase
Controller
  • JSC-2D Digital PID Controller
  • ±0.1 oC Digital PID Controller
  • Automatic START/STOP timer
  • Dual LED displays temperature and remaining time
  • Temperature calibration function
  • Auto-tuning function
  • Class A Pt-100 Ω sensor
Construction
  • Vertical loading type chamber with 2 ea service baskets
  • Light weight self balanced door with safety lock
  • Stainless steel 304 (AISI 304) chamber, lid and top plate to protect from corrosion by water and steam
  • Special plated heating element provides resistant to dry-burn, corrosion and guarantee long life in repeated use
  • Two Stainless Steel Wire Basket included
Performance
  • Maximum sterilization temperature and pressure up to 123 oC and 0.12 Mpa
  • Automatic sterilization cycle starts just by setting sterilization temperature and time
  • Validation compliance performance with accuracy within ± 0.5 oC and uniformity within ± 2.0 oC
Convenience
  • Two steam collection bottles removes most of steam generated during operation for comfortable laboratory environment
  • Equipped with drain valve for cleaning and changing with fresh water
  • High pressure and temperature resistant silicone gasket
  • Built-in analog pressure gauge
  • Manual pressure release valve
  • Caster for easy transport
Safety
  • SAFETY DOOR LOCK Door interlocking system integrated with high temperature, pressure and electric cut-off
  • TRIPLE OVER-TEMP. CUT-OFF
  • Controller cut-off heater and AUDIO VISUAL ALARMS in case +2 oC above set temperature
  • MAX TEMP CUT-OFF heater and AUDIO VISUAL ALARM when +1 oC above maximum limit (123 oC )
  • Analog system cut-off heater 10% above set temp.
  • DUAL OVER-PRESSURE CUT-OFF
  • Controller open valve and AUDIO VISUAL ALARMS in case +2 oC above set temperature or +1 oC above maximum limit (123 oC )
  • Mechanical over pressure valve release pressure automatically in case exceeding pressure limit
  • ANALOG PRESSURE GAUGE 0 ~ 0.3 Mpa pressure gauge indicating actual pressure
  • MANUAL PRESSURE RELEASE VALVE for emergency
  • OVER CURRENT CUT-OFF : Electrical Leakage Breaker

BLOCK HEATER

Specifications
  • Temp. Range : ambient +5 ~ 150℃
  • Controller : Digital PID Controller
  • Accuracy : ± 0.2℃ at 60℃
  • Blocks : Aluminum, Interchangeable
  • Capacity : 1 / 2/ 4 Blocks
Model JSBL-01T JSBL-02T JSBL-04T
Block Capacity 1 Block 2 Block 4 Block
Temp. Heating Type Plate heater by heat conduction
Range ambient +5℃ ~ 150℃
Accuracy ±0.2 ℃ at 60.0℃
Uniformity ±0.2 ℃ at 60.0℃
Control Main Controller Digital Programmable Microprocessor PID Controller
Wait off Timer mm:ss / hh:mm / Continuous Selectable
Sensor Pt 100 Ω
Safety Device Temp. Hydraulic Over Temperature Protection Safety Dvice
Electrical Electrical Leakage Breaker
Electrical Requirement 220 VAC 50 Hz or 220 VAC 60 Hz

 

 

Digital PID Control
  • Up to 150℃, ± 0.2℃ accuracy and ± 0.2℃ niformity Digital PID Controller enables ± 0.1℃ resolution Over Temperature Protection, Alarm, Timer, Auto-tuning

DRY HEAT STERILIZER

Specifications
  • Dry Heat Sterilizer is a common instrument to be used to drying, heating and sterilizing objects by heating air up to 160 oC or 180 oC with gravity or forced convection system during specified sterilizing exposure time range from 30 to 60 minutes of sterilization exposure time
Art No. JSOF-030S JSOF-050S JSON-030S JSON-050S
Hot Air Circulation Forced Convection Gravity Convection
Chamber Volume (Capacity) 33 L 48 L 33 L 48 L
Dimensions Inner 350 x 270 x 350 400 x 300 x 400 350 x 270 x 350 400 x 300 x 400
W x D x H mm Outer 510 x 570 x 660 560 x 585 x 710 510 x 490 x 660 560 x 505 x 710
Temperature Range ambient +10 oC to 250 oC
Accuracy at 180 oC ± 0.2 oC ± 0.2 oC ± 0.3 oC ± 0.3 oC
Uniformity at 180 oC ± 1.0 oC ± 1.0 oC ± 2.0 oC ± 2.0 oC
Heat up time to 180 oC 15 min.
No. of Shelves / Max. No. 2/12 2/12 10-Feb 12-Mar
No. of Ventilation damper 1
Heater Capacity 800 W 1.0 kW 800 W 1.2 kW
Power Rating 3.8 Amp 4.7 Amp 3.8 Amp 5.5 Amp
Controller
  • JSC-0D Digital PID Controller
  • ±0.1 oC Digital PID Controller with LED Display
  • Automatic START/STOP timer
  • Adjustable timer scale 99min 59sec / 99hr 59min / 99 day 23hr or continuous operation
  • Temperature calibration function
  • Auto-tuning function
  • Class A Pt-100 Ω sensor
Construction
  • Durable epoxy powder coated metallic casing
  • Ventilation damper
  • Corrosion resistant Stainless Steel 304 chamber with seamless round cornered edge allows easy cleaning and prevent leakage
Performance
  • Choice of Forced or Gravity air convection
  • Separate heating compartment prevents contamination and maintenance free
  • 50mm thick high thermal efficiency mineral wool with woven aluminum barrier sheet save energy and less dust
Convenience
  • Stainless Steel 304 Chamber with seamless round cornered edge allows easy cleaning and prevent leakage
  • Removable and height adjustable shelf by 25mm spacing
  • Easy to open and air-tight one touch door latch
  • Opening size adjustable ventilation damper
  • Non-contact door switch cut-off heater and/or blower
Safety
  • DUAL OVER TEMP. CUT-OFF
  • Digital system cut-off heater and AUDIO VISUAL ALARM in case +2 oC above set temperature
  • Analog system cut-off heater 10% above set temp.
  • MAX TEMP CUT-OFF heater and AUDIO VISUAL ALARM when +1 oC above maximum limit
  • DOOR SENSOR : Non-contact magnetic door switch cut-off heater and blower when door opened
  • SENSOR DISCONNECTION ALARM
  • OVER CURRENT CUT-OFF : Electrical Leakage Breaker